Ring surface measurement coupon
ADCA found it natural to develop a removable annular coupon (T2A) in order to make the potential measurement even more precise.
Due to its annular construction, the T2A makes it possible to significantly reduce the RI between the electrode and the witness (54 dB). The wandering gradients are also diverted by taking the periphery of the annular witness and interfere very little in the measurement.
Placing the electrode in the center of the witness removes the ambiguities of the electrode/control position. The weight and center of gravity of the T2A ensure that the electrode is in a stable position and does not fall.